Basic Information
Weighing indicator3190-A12e
Accuracy Class: III
Scale interval n=3000
Input Signal 1.0~2.0 MV/V
Technical parameters
Model: 3190-A12e Weighing Indicator
Class: III
Scale interval n=3000
Input Signal: 1.0~2.0 MV/V
A/D Conversion Speed: 40 times/second
Bridge voltage: 5V DC; can drive 4 x 350W or 8 x 700W sensors
A/D identification code: 300,000
Voltage: 220V 50HZ
Internally equipped with a 6V/10Ah maintenance-free battery, providing up to 24 hours of continuous operation after charging.
Operating temperature: -10℃ to 40℃; Operating humidity: <85%RH.
Operation
1.Press the power switch to turn on the power.
2.Press and hold the zero button for 2 seconds. The displayed value will be reset to zero, and the [0] indicator light will illuminate.
3.Actual weight after removing tare: With the indicator light off, and the weight greater than zero and stable, press the [0] key. The displayed value will reset to zero, and the indicator light will illuminate.
4.Clear the tare Weight: With the indicator light on, press the [→0←] key to clear the tare weight. The indicator light will then turn off.
5.Battery Level: The display shows [Pbt 85] when the device is powered on and off, indicating a battery level of 85%.
6.Charging reminder: The display flashes when the battery level is below 15% to remind the user to charge the device.
7.Over-Discharge Protection: The device automatically shuts down when the battery level reaches zero to prevent over-discharge
8.Power Saving Mode: If the automatic shutdown function is set, the display will show [-] after 3 minutes of inactivity to reduce battery consumption.
9.Automatic Shutdown: If the automatic shutdown function is set, the machine will automatically shut down after 15 minutes of inactivity.
10.Working Time: Equipped with a 10.0AH maintenance-free battery, a full charge allows for 24 hours of continuous operation.